dts: update to v4.18-rc1
Signed-off-by: Sascha Hauer <s.hauer@pengutronix.de>
Diffstat (limited to 'dts/Bindings/hwmon')
-rw-r--r-- | dts/Bindings/hwmon/gpio-fan.txt | 2 | ||||
-rw-r--r-- | dts/Bindings/hwmon/ltc2990.txt | 36 |
2 files changed, 37 insertions, 1 deletions
diff --git a/dts/Bindings/hwmon/gpio-fan.txt b/dts/Bindings/hwmon/gpio-fan.txt index 439a7430fc..2becdcfdc8 100644 --- a/dts/Bindings/hwmon/gpio-fan.txt +++ b/dts/Bindings/hwmon/gpio-fan.txt @@ -11,7 +11,7 @@ Optional properties: must have the RPM values in ascending order. - alarm-gpios: This pin going active indicates something is wrong with the fan, and a udev event will be fired. -- cooling-cells: If used as a cooling device, must be <2> +- #cooling-cells: If used as a cooling device, must be <2> Also see: Documentation/devicetree/bindings/thermal/thermal.txt min and max states are derived from the speed-map of the fan. diff --git a/dts/Bindings/hwmon/ltc2990.txt b/dts/Bindings/hwmon/ltc2990.txt new file mode 100644 index 0000000000..f92f54029e --- /dev/null +++ b/dts/Bindings/hwmon/ltc2990.txt @@ -0,0 +1,36 @@ +ltc2990: Linear Technology LTC2990 power monitor + +Required properties: +- compatible: Must be "lltc,ltc2990" +- reg: I2C slave address +- lltc,meas-mode: + An array of two integers for configuring the chip measurement mode. + + The first integer defines the bits 2..0 in the control register. In all + cases the internal temperature and supply voltage are measured. In + addition the following input measurements are enabled per mode: + + 0: V1, V2, TR2 + 1: V1-V2, TR2 + 2: V1-V2, V3, V4 + 3: TR1, V3, V4 + 4: TR1, V3-V4 + 5: TR1, TR2 + 6: V1-V2, V3-V4 + 7: V1, V2, V3, V4 + + The second integer defines the bits 4..3 in the control register. This + allows a subset of the measurements to be enabled: + + 0: Internal temperature and supply voltage only + 1: TR1, V1 or V1-V2 only per mode + 2: TR2, V3 or V3-V4 only per mode + 3: All measurements per mode + +Example: + +ltc2990@4c { + compatible = "lltc,ltc2990"; + reg = <0x4c>; + lltc,meas-mode = <7 3>; /* V1, V2, V3, V4 */ +}; |