summaryrefslogtreecommitdiffstats
path: root/dts/Bindings/net/micrel-ksz90x1.txt
diff options
context:
space:
mode:
authorSascha Hauer <s.hauer@pengutronix.de>2014-06-17 22:16:07 +0200
committerSascha Hauer <s.hauer@pengutronix.de>2014-06-19 09:41:51 +0200
commit9313920df6d3d55fbd03ce8ec1c0da9a10c29824 (patch)
treeef80d80abbaf46293b777ead52caddd9d5d97644 /dts/Bindings/net/micrel-ksz90x1.txt
parent83e875e1f45beffe399cff0ff6128e0fca9da168 (diff)
downloadbarebox-9313920df6d3d55fbd03ce8ec1c0da9a10c29824.tar.gz
barebox-9313920df6d3d55fbd03ce8ec1c0da9a10c29824.tar.xz
dts: update to v3.16-rc1
Signed-off-by: Sascha Hauer <s.hauer@pengutronix.de>
Diffstat (limited to 'dts/Bindings/net/micrel-ksz90x1.txt')
-rw-r--r--dts/Bindings/net/micrel-ksz90x1.txt83
1 files changed, 83 insertions, 0 deletions
diff --git a/dts/Bindings/net/micrel-ksz90x1.txt b/dts/Bindings/net/micrel-ksz90x1.txt
new file mode 100644
index 0000000000..692076fda0
--- /dev/null
+++ b/dts/Bindings/net/micrel-ksz90x1.txt
@@ -0,0 +1,83 @@
+Micrel KSZ9021/KSZ9031 Gigabit Ethernet PHY
+
+Some boards require special tuning values, particularly when it comes to
+clock delays. You can specify clock delay values by adding
+micrel-specific properties to an Ethernet OF device node.
+
+Note that these settings are applied after any phy-specific fixup from
+phy_fixup_list (see phy_init_hw() from drivers/net/phy/phy_device.c),
+and therefore may overwrite them.
+
+KSZ9021:
+
+ All skew control options are specified in picoseconds. The minimum
+ value is 0, the maximum value is 3000, and it is incremented by 200ps
+ steps.
+
+ Optional properties:
+
+ - rxc-skew-ps : Skew control of RXC pad
+ - rxdv-skew-ps : Skew control of RX CTL pad
+ - txc-skew-ps : Skew control of TXC pad
+ - txen-skew-ps : Skew control of TX CTL pad
+ - rxd0-skew-ps : Skew control of RX data 0 pad
+ - rxd1-skew-ps : Skew control of RX data 1 pad
+ - rxd2-skew-ps : Skew control of RX data 2 pad
+ - rxd3-skew-ps : Skew control of RX data 3 pad
+ - txd0-skew-ps : Skew control of TX data 0 pad
+ - txd1-skew-ps : Skew control of TX data 1 pad
+ - txd2-skew-ps : Skew control of TX data 2 pad
+ - txd3-skew-ps : Skew control of TX data 3 pad
+
+KSZ9031:
+
+ All skew control options are specified in picoseconds. The minimum
+ value is 0, and the maximum is property-dependent. The increment
+ step is 60ps.
+
+ Optional properties:
+
+ Maximum value of 1860:
+
+ - rxc-skew-ps : Skew control of RX clock pad
+ - txc-skew-ps : Skew control of TX clock pad
+
+ Maximum value of 900:
+
+ - rxdv-skew-ps : Skew control of RX CTL pad
+ - txen-skew-ps : Skew control of TX CTL pad
+ - rxd0-skew-ps : Skew control of RX data 0 pad
+ - rxd1-skew-ps : Skew control of RX data 1 pad
+ - rxd2-skew-ps : Skew control of RX data 2 pad
+ - rxd3-skew-ps : Skew control of RX data 3 pad
+ - txd0-skew-ps : Skew control of TX data 0 pad
+ - txd1-skew-ps : Skew control of TX data 1 pad
+ - txd2-skew-ps : Skew control of TX data 2 pad
+ - txd3-skew-ps : Skew control of TX data 3 pad
+
+Examples:
+
+ /* Attach to an Ethernet device with autodetected PHY */
+ &enet {
+ rxc-skew-ps = <3000>;
+ rxdv-skew-ps = <0>;
+ txc-skew-ps = <3000>;
+ txen-skew-ps = <0>;
+ status = "okay";
+ };
+
+ /* Attach to an explicitly-specified PHY */
+ mdio {
+ phy0: ethernet-phy@0 {
+ rxc-skew-ps = <3000>;
+ rxdv-skew-ps = <0>;
+ txc-skew-ps = <3000>;
+ txen-skew-ps = <0>;
+ reg = <0>;
+ };
+ };
+ ethernet@70000 {
+ status = "okay";
+ phy = <&phy0>;
+ phy-mode = "rgmii-id";
+ };