diff options
Diffstat (limited to 'dts/Bindings/iio/afe/voltage-divider.txt')
-rw-r--r-- | dts/Bindings/iio/afe/voltage-divider.txt | 53 |
1 files changed, 0 insertions, 53 deletions
diff --git a/dts/Bindings/iio/afe/voltage-divider.txt b/dts/Bindings/iio/afe/voltage-divider.txt deleted file mode 100644 index b452a84061..0000000000 --- a/dts/Bindings/iio/afe/voltage-divider.txt +++ /dev/null @@ -1,53 +0,0 @@ -Voltage divider -=============== - -When an io-channel measures the midpoint of a voltage divider, the -interesting voltage is often the voltage over the full resistance -of the divider. This binding describes the voltage divider in such -a curcuit. - - Vin ----. - | - .-----. - | R | - '-----' - | - +---- Vout - | - .-----. - | Rout| - '-----' - | - GND - -Required properties: -- compatible : "voltage-divider" -- io-channels : Channel node of a voltage io-channel measuring Vout. -- output-ohms : Resistance Rout over which the output voltage is measured. - See full-ohms. -- full-ohms : Resistance R + Rout for the full divider. The io-channel - is scaled by the Rout / (R + Rout) quotient. - -Example: -The system voltage is circa 12V, but divided down with a 22/222 -voltage divider (R = 200 Ohms, Rout = 22 Ohms) and fed to an ADC. - -sysv { - compatible = "voltage-divider"; - io-channels = <&maxadc 1>; - - /* Scale the system voltage by 22/222 to fit the ADC range. */ - output-ohms = <22>; - full-ohms = <222>; /* 200 + 22 */ -}; - -&spi { - maxadc: adc@0 { - compatible = "maxim,max1027"; - reg = <0>; - #io-channel-cells = <1>; - interrupt-parent = <&gpio5>; - interrupts = <15 IRQ_TYPE_EDGE_RISING>; - spi-max-frequency = <1000000>; - }; -}; |