summaryrefslogtreecommitdiffstats
path: root/dts/Bindings/net/dsa/ocelot.txt
diff options
context:
space:
mode:
Diffstat (limited to 'dts/Bindings/net/dsa/ocelot.txt')
-rw-r--r--dts/Bindings/net/dsa/ocelot.txt213
1 files changed, 0 insertions, 213 deletions
diff --git a/dts/Bindings/net/dsa/ocelot.txt b/dts/Bindings/net/dsa/ocelot.txt
deleted file mode 100644
index 7a271d070b..0000000000
--- a/dts/Bindings/net/dsa/ocelot.txt
+++ /dev/null
@@ -1,213 +0,0 @@
-Microchip Ocelot switch driver family
-=====================================
-
-Felix
------
-
-Currently the switches supported by the felix driver are:
-
-- VSC9959 (Felix)
-- VSC9953 (Seville)
-
-The VSC9959 switch is found in the NXP LS1028A. It is a PCI device, part of the
-larger ENETC root complex. As a result, the ethernet-switch node is a sub-node
-of the PCIe root complex node and its "reg" property conforms to the parent
-node bindings:
-
-* reg: Specifies PCIe Device Number and Function Number of the endpoint device,
- in this case for the Ethernet L2Switch it is PF5 (of device 0, bus 0).
-
-It does not require a "compatible" string.
-
-The interrupt line is used to signal availability of PTP TX timestamps and for
-TSN frame preemption.
-
-For the external switch ports, depending on board configuration, "phy-mode" and
-"phy-handle" are populated by board specific device tree instances. Ports 4 and
-5 are fixed as internal ports in the NXP LS1028A instantiation.
-
-The CPU port property ("ethernet") configures the feature called "NPI port" in
-the Ocelot hardware core. The CPU port in Ocelot is a set of queues, which are
-connected, in the Node Processor Interface (NPI) mode, to an Ethernet port.
-By default, in fsl-ls1028a.dtsi, the NPI port is assigned to the internal
-2.5Gbps port@4, but can be moved to the 1Gbps port@5, depending on the specific
-use case. Moving the NPI port to an external switch port is hardware possible,
-but there is no platform support for the Linux system on the LS1028A chip to
-operate as an entire slave DSA chip. NPI functionality (and therefore DSA
-tagging) is supported on a single port at a time.
-
-Any port can be disabled (and in fsl-ls1028a.dtsi, they are indeed all disabled
-by default, and should be enabled on a per-board basis). But if any external
-switch port is enabled at all, the ENETC PF2 (enetc_port2) should be enabled as
-well, regardless of whether it is configured as the DSA master or not. This is
-because the Felix PHYLINK implementation accesses the MAC PCS registers, which
-in hardware truly belong to the ENETC port #2 and not to Felix.
-
-Supported PHY interface types (appropriate SerDes protocol setting changes are
-needed in the RCW binary):
-
-* phy_mode = "internal": on ports 4 and 5
-* phy_mode = "sgmii": on ports 0, 1, 2, 3
-* phy_mode = "qsgmii": on ports 0, 1, 2, 3
-* phy_mode = "usxgmii": on ports 0, 1, 2, 3
-* phy_mode = "2500base-x": on ports 0, 1, 2, 3
-
-For the rest of the device tree binding definitions, which are standard DSA and
-PCI, refer to the following documents:
-
-Documentation/devicetree/bindings/net/dsa/dsa.txt
-Documentation/devicetree/bindings/pci/pci.txt
-
-Example:
-
-&soc {
- pcie@1f0000000 { /* Integrated Endpoint Root Complex */
- ethernet-switch@0,5 {
- reg = <0x000500 0 0 0 0>;
- /* IEP INT_B */
- interrupts = <GIC_SPI 95 IRQ_TYPE_LEVEL_HIGH>;
-
- ports {
- #address-cells = <1>;
- #size-cells = <0>;
-
- /* External ports */
- port@0 {
- reg = <0>;
- label = "swp0";
- };
-
- port@1 {
- reg = <1>;
- label = "swp1";
- };
-
- port@2 {
- reg = <2>;
- label = "swp2";
- };
-
- port@3 {
- reg = <3>;
- label = "swp3";
- };
-
- /* Tagging CPU port */
- port@4 {
- reg = <4>;
- ethernet = <&enetc_port2>;
- phy-mode = "internal";
-
- fixed-link {
- speed = <2500>;
- full-duplex;
- };
- };
-
- /* Non-tagging CPU port */
- port@5 {
- reg = <5>;
- phy-mode = "internal";
- status = "disabled";
-
- fixed-link {
- speed = <1000>;
- full-duplex;
- };
- };
- };
- };
- };
-};
-
-The VSC9953 switch is found inside NXP T1040. It is a platform device with the
-following required properties:
-
-- compatible:
- Must be "mscc,vsc9953-switch".
-
-Supported PHY interface types (appropriate SerDes protocol setting changes are
-needed in the RCW binary):
-
-* phy_mode = "internal": on ports 8 and 9
-* phy_mode = "sgmii": on ports 0, 1, 2, 3, 4, 5, 6, 7
-* phy_mode = "qsgmii": on ports 0, 1, 2, 3, 4, 5, 6, 7
-
-Example:
-
-&soc {
- ethernet-switch@800000 {
- #address-cells = <0x1>;
- #size-cells = <0x0>;
- compatible = "mscc,vsc9953-switch";
- little-endian;
- reg = <0x800000 0x290000>;
-
- ports {
- #address-cells = <0x1>;
- #size-cells = <0x0>;
-
- port@0 {
- reg = <0x0>;
- label = "swp0";
- };
-
- port@1 {
- reg = <0x1>;
- label = "swp1";
- };
-
- port@2 {
- reg = <0x2>;
- label = "swp2";
- };
-
- port@3 {
- reg = <0x3>;
- label = "swp3";
- };
-
- port@4 {
- reg = <0x4>;
- label = "swp4";
- };
-
- port@5 {
- reg = <0x5>;
- label = "swp5";
- };
-
- port@6 {
- reg = <0x6>;
- label = "swp6";
- };
-
- port@7 {
- reg = <0x7>;
- label = "swp7";
- };
-
- port@8 {
- reg = <0x8>;
- phy-mode = "internal";
- ethernet = <&enet0>;
-
- fixed-link {
- speed = <2500>;
- full-duplex;
- };
- };
-
- port@9 {
- reg = <0x9>;
- phy-mode = "internal";
- status = "disabled";
-
- fixed-link {
- speed = <2500>;
- full-duplex;
- };
- };
- };
- };
-};