+Thermal driver for MAX77620 Power management IC from Maxim Semiconductor.
+
+Maxim Semiconductor MAX77620 supports alarm interrupts when its
+die temperature crosses 120C and 140C. These threshold temperatures
+are not configurable. Device does not provide the real temperature
+of die other than just indicating whether temperature is above or
+below threshold level.
+
+Required properties:
+-------------------
+#thermal-sensor-cells: Please refer <devicetree/bindings/thermal/thermal.txt>
+ for more details.
+ The value must be 0.
+
+For more details, please refer generic thermal DT binding document
+<devicetree/bindings/thermal/thermal.txt>.
+
+Please refer <devicetree/bindings/mfd/max77620.txt> for mfd DT binding
+document for the MAX77620.
+
+Example:
+--------
+#include <dt-bindings/mfd/max77620.h>
+#include <dt-bindings/thermal/thermal.h>
+...
+
+i2c@7000d000 {
+ spmic: max77620@3c {
+ compatible = "maxim,max77620";
+ :::::
+ #thermal-sensor-cells = <0>;
+ :::
+ };
+};
+
+cool_dev: cool-dev {
+ compatible = "cooling-dev";
+ #cooling-cells = <2>;
+};
+
+thermal-zones {
+ PMIC-Die {
+ polling-delay = <0>;
+ polling-delay-passive = <0>;
+ thermal-sensors = <&spmic>;
+
+ trips {
+ pmic_die_warn_temp_thresh: hot-die {
+ temperature = <120000>;
+ type = "hot";
+ hysteresis = <0>;
+ };
+
+ pmic_die_cirt_temp_thresh: cirtical-die {
+ temperature = <140000>;
+ type = "critical";
+ hysteresis = <0>;
+ };
+ };
+
+ cooling-maps {
+ map0 {
+ trip = <&pmic_die_warn_temp_thresh>;
+ cooling-device = <&cool_dev THERMAL_NO_LIMIT
+ THERMAL_NO_LIMIT>;
+ contribution = <100>;
+ };
+ };
+ };
+};