-Tegra124 SOCTHERM thermal management system
-
-The SOCTHERM IP block contains thermal sensors, support for polled
-or interrupt-based thermal monitoring, CPU and GPU throttling based
-on temperature trip points, and handling external overcurrent
-notifications. It is also used to manage emergency shutdown in an
-overheating situation.
-
-Required properties :
-- compatible : For Tegra124, must contain "nvidia,tegra124-soctherm".
- For Tegra132, must contain "nvidia,tegra132-soctherm".
- For Tegra210, must contain "nvidia,tegra210-soctherm".
-- reg : Should contain at least 2 entries for each entry in reg-names:
- - SOCTHERM register set
- - Tegra CAR register set: Required for Tegra124 and Tegra210.
- - CCROC register set: Required for Tegra132.
-- reg-names : Should contain at least 2 entries:
- - soctherm-reg
- - car-reg
- - ccroc-reg
-- interrupts : Defines the interrupt used by SOCTHERM
-- clocks : Must contain an entry for each entry in clock-names.
- See ../clocks/clock-bindings.txt for details.
-- clock-names : Must include the following entries:
- - tsensor
- - soctherm
-- resets : Must contain an entry for each entry in reset-names.
- See ../reset/reset.txt for details.
-- reset-names : Must include the following entries:
- - soctherm
-- #thermal-sensor-cells : Should be 1. For a description of this property, see
- Documentation/devicetree/bindings/thermal/thermal-sensor.yaml.
- See <dt-bindings/thermal/tegra124-soctherm.h> for a list of valid values
- when referring to thermal sensors.
-- throttle-cfgs: A sub-node which is a container of configuration for each
- hardware throttle events. These events can be set as cooling devices.
- * throttle events: Sub-nodes must be named as "light" or "heavy".
- Properties:
- - nvidia,priority: Each throttles has its own throttle settings, so the
- SW need to set priorities for various throttle, the HW arbiter can select
- the final throttle settings.
- Bigger value indicates higher priority, In general, higher priority
- translates to lower target frequency. SW needs to ensure that critical
- thermal alarms are given higher priority, and ensure that there is
- no race if priority of two vectors is set to the same value.
- The range of this value is 1~100.
- - nvidia,cpu-throt-percent: This property is for Tegra124 and Tegra210.
- It is the throttling depth of pulse skippers, it's the percentage
- throttling.
- - nvidia,cpu-throt-level: This property is only for Tegra132, it is the
- level of pulse skippers, which used to throttle clock frequencies. It
- indicates cpu clock throttling depth, and the depth can be programmed.
- Must set as following values:
- TEGRA_SOCTHERM_THROT_LEVEL_LOW, TEGRA_SOCTHERM_THROT_LEVEL_MED
- TEGRA_SOCTHERM_THROT_LEVEL_HIGH, TEGRA_SOCTHERM_THROT_LEVEL_NONE
- - nvidia,gpu-throt-level: This property is for Tegra124 and Tegra210.
- It is the level of pulse skippers, which used to throttle clock
- frequencies. It indicates gpu clock throttling depth and can be
- programmed to any of the following values which represent a throttling
- percentage:
- TEGRA_SOCTHERM_THROT_LEVEL_NONE (0%)
- TEGRA_SOCTHERM_THROT_LEVEL_LOW (50%),
- TEGRA_SOCTHERM_THROT_LEVEL_MED (75%),
- TEGRA_SOCTHERM_THROT_LEVEL_HIGH (85%).
- - #cooling-cells: Should be 1. This cooling device only support on/off state.
- For a description of this property see:
- Documentation/devicetree/bindings/thermal/thermal-cooling-devices.yaml
-
- Optional properties: The following properties are T210 specific and
- valid only for OCx throttle events.
- - nvidia,count-threshold: Specifies the number of OC events that are
- required for triggering an interrupt. Interrupts are not triggered if
- the property is missing. A value of 0 will interrupt on every OC alarm.
- - nvidia,polarity-active-low: Configures the polarity of the OC alaram
- signal. If present, this means assert low, otherwise assert high.
- - nvidia,alarm-filter: Number of clocks to filter event. When the filter
- expires (which means the OC event has not occurred for a long time),
- the counter is cleared and filter is rearmed. Default value is 0.
- - nvidia,throttle-period-us: Specifies the number of uSec for which
- throttling is engaged after the OC event is deasserted. Default value
- is 0.
-
-Optional properties:
-- nvidia,thermtrips : When present, this property specifies the temperature at
- which the soctherm hardware will assert the thermal trigger signal to the
- Power Management IC, which can be configured to reset or shutdown the device.
- It is an array of pairs where each pair represents a tsensor id followed by a
- temperature in milli Celcius. In the absence of this property the critical
- trip point will be used for thermtrip temperature.
-
-Note:
-- the "critical" type trip points will be used to set the temperature at which
-the SOC_THERM hardware will assert a thermal trigger if the "nvidia,thermtrips"
-property is missing. When the thermtrips property is present, the breach of a
-critical trip point is reported back to the thermal framework to implement
-software shutdown.
-
-- the "hot" type trip points will be set to SOC_THERM hardware as the throttle
-temperature. Once the the temperature of this thermal zone is higher
-than it, it will trigger the HW throttle event.
-
-Example :
-
- soctherm@700e2000 {
- compatible = "nvidia,tegra124-soctherm";
- reg = <0x0 0x700e2000 0x0 0x600 /* SOC_THERM reg_base */
- 0x0 0x60006000 0x0 0x400 /* CAR reg_base */
- reg-names = "soctherm-reg", "car-reg";
- interrupts = <GIC_SPI 48 IRQ_TYPE_LEVEL_HIGH>;
- clocks = <&tegra_car TEGRA124_CLK_TSENSOR>,
- <&tegra_car TEGRA124_CLK_SOC_THERM>;
- clock-names = "tsensor", "soctherm";
- resets = <&tegra_car 78>;
- reset-names = "soctherm";
-
- #thermal-sensor-cells = <1>;
-
- nvidia,thermtrips = <TEGRA124_SOCTHERM_SENSOR_CPU 102500
- TEGRA124_SOCTHERM_SENSOR_GPU 103000>;
-
- throttle-cfgs {
- /*
- * When the "heavy" cooling device triggered,
- * the HW will skip cpu clock's pulse in 85% depth,
- * skip gpu clock's pulse in 85% level
- */
- throttle_heavy: heavy {
- nvidia,priority = <100>;
- nvidia,cpu-throt-percent = <85>;
- nvidia,gpu-throt-level = <TEGRA_SOCTHERM_THROT_LEVEL_HIGH>;
-
- #cooling-cells = <1>;
- };
-
- /*
- * When the "light" cooling device triggered,
- * the HW will skip cpu clock's pulse in 50% depth,
- * skip gpu clock's pulse in 50% level
- */
- throttle_light: light {
- nvidia,priority = <80>;
- nvidia,cpu-throt-percent = <50>;
- nvidia,gpu-throt-level = <TEGRA_SOCTHERM_THROT_LEVEL_LOW>;
-
- #cooling-cells = <1>;
- };
-
- /*
- * If these two devices are triggered in same time, the HW throttle
- * arbiter will select the highest priority as the final throttle
- * settings to skip cpu pulse.
- */
-
- throttle_oc1: oc1 {
- nvidia,priority = <50>;
- nvidia,polarity-active-low;
- nvidia,count-threshold = <100>;
- nvidia,alarm-filter = <5100000>;
- nvidia,throttle-period-us = <0>;
- nvidia,cpu-throt-percent = <75>;
- nvidia,gpu-throt-level =
- <TEGRA_SOCTHERM_THROT_LEVEL_MED>;
- };
- };
- };
-
-Example: referring to Tegra132's "reg", "reg-names" and "throttle-cfgs" :
-
- soctherm@700e2000 {
- compatible = "nvidia,tegra132-soctherm";
- reg = <0x0 0x700e2000 0x0 0x600 /* SOC_THERM reg_base */
- 0x0 0x70040000 0x0 0x200>; /* CCROC reg_base */;
- reg-names = "soctherm-reg", "ccroc-reg";
-
- throttle-cfgs {
- /*
- * When the "heavy" cooling device triggered,
- * the HW will skip cpu clock's pulse in HIGH level
- */
- throttle_heavy: heavy {
- nvidia,priority = <100>;
- nvidia,cpu-throt-level = <TEGRA_SOCTHERM_THROT_LEVEL_HIGH>;
-
- #cooling-cells = <1>;
- };
-
- /*
- * When the "light" cooling device triggered,
- * the HW will skip cpu clock's pulse in MED level
- */
- throttle_light: light {
- nvidia,priority = <80>;
- nvidia,cpu-throt-level = <TEGRA_SOCTHERM_THROT_LEVEL_MED>;
-
- #cooling-cells = <1>;
- };
-
- /*
- * If these two devices are triggered in same time, the HW throttle
- * arbiter will select the highest priority as the final throttle
- * settings to skip cpu pulse.
- */
-
- };
- };
-
-Example: referring to thermal sensors :
-
- thermal-zones {
- cpu {
- polling-delay-passive = <1000>;
- polling-delay = <1000>;
-
- thermal-sensors =
- <&soctherm TEGRA124_SOCTHERM_SENSOR_CPU>;
-
- trips {
- cpu_shutdown_trip: shutdown-trip {
- temperature = <102500>;
- hysteresis = <1000>;
- type = "critical";
- };
-
- cpu_throttle_trip: throttle-trip {
- temperature = <100000>;
- hysteresis = <1000>;
- type = "hot";
- };
- };
-
- cooling-maps {
- map0 {
- trip = <&cpu_throttle_trip>;
- cooling-device = <&throttle_heavy 1 1>;
- };
- };
- };
- };