diff --git a/dts/Bindings/thermal/thermal-zones.yaml b/dts/Bindings/thermal/thermal-zones.yaml
index a07de5ed0c..dbd52620d2 100644
--- a/dts/Bindings/thermal/thermal-zones.yaml
+++ b/dts/Bindings/thermal/thermal-zones.yaml
@@ -5,10 +5,10 @@
$id: http://devicetree.org/schemas/thermal/thermal-zones.yaml#
$schema: http://devicetree.org/meta-schemas/base.yaml#
-title: Thermal zone binding
+title: Thermal zone
maintainers:
- - Amit Kucheria <amitk@kernel.org>
+ - Daniel Lezcano <daniel.lezcano@linaro.org>
description: |
Thermal management is achieved in devicetree by describing the sensor hardware
@@ -75,6 +75,22 @@ patternProperties:
framework and assumes that the thermal sensors in this zone
support interrupts.
+ critical-action:
+ $ref: /schemas/types.yaml#/definitions/string
+ description: |
+ The action the OS should perform after the critical temperature is reached.
+ By default the system will shutdown as a safe action to prevent damage
+ to the hardware, if the property is not set.
+ The shutdown action should be always the default and preferred one.
+ Choose 'reboot' with care, as the hardware may be in thermal stress,
+ thus leading to infinite reboots that may cause damage to the hardware.
+ Make sure the firmware/bootloader will act as the last resort and take
+ over the thermal control.
+
+ enum:
+ - shutdown
+ - reboot
+
thermal-sensors:
$ref: /schemas/types.yaml#/definitions/phandle-array
maxItems: 1
@@ -171,6 +187,7 @@ patternProperties:
cooling-maps:
type: object
+ additionalProperties: false
description:
This node describes the action to be taken when a thermal zone
crosses one of the temperature thresholds described in the trips
@@ -199,12 +216,11 @@ patternProperties:
contribution:
$ref: /schemas/types.yaml#/definitions/uint32
- minimum: 0
- maximum: 100
description:
- The percentage contribution of the cooling devices at the
- specific trip temperature referenced in this map
- to this thermal zone
+ The cooling contribution to the thermal zone of the referred
+ cooling device at the referred trip point. The contribution is
+ a ratio of the sum of all cooling contributions within a
+ thermal zone.
required:
- trip
@@ -215,6 +231,7 @@ patternProperties:
- polling-delay
- polling-delay-passive
- thermal-sensors
+ - trips
additionalProperties: false