+++ b/dts/Bindings/thermal/uniphier-thermal.txt
@@ -0,0 +1,64 @@
+* UniPhier Thermal bindings
+
+This describes the devicetree bindings for thermal monitor supported by
+PVT(Process, Voltage and Temperature) monitoring unit implemented on Socionext
+UniPhier SoCs.
+
+Required properties:
+- compatible :
+ - "socionext,uniphier-pxs2-thermal" : For UniPhier PXs2 SoC
+ - "socionext,uniphier-ld20-thermal" : For UniPhier LD20 SoC
+- interrupts : IRQ for the temperature alarm
+- #thermal-sensor-cells : Should be 0. See ./thermal.txt for details.
+
+Optional properties:
+- socionext,tmod-calibration: A pair of calibrated values referred from PVT,
+ in case that the values aren't set on SoC,
+ like a reference board.
+
+Example:
+
+ sysctrl@61840000 {
+ compatible = "socionext,uniphier-ld20-sysctrl",
+ "simple-mfd", "syscon";
+ reg = <0x61840000 0x10000>;
+ ...
+ pvtctl: pvtctl {
+ compatible = "socionext,uniphier-ld20-thermal";
+ interrupts = <0 3 1>;
+ #thermal-sensor-cells = <0>;
+ };
+ ...
+ };
+
+ thermal-zones {
+ cpu_thermal {
+ polling-delay-passive = <250>; /* 250ms */
+ polling-delay = <1000>; /* 1000ms */
+ thermal-sensors = <&pvtctl>;
+
+ trips {
+ cpu_crit: cpu_crit {
+ temperature = <110000>; /* 110C */
+ hysteresis = <2000>;
+ type = "critical";
+ };
+ cpu_alert: cpu_alert {
+ temperature = <100000>; /* 100C */
+ hysteresis = <2000>;
+ type = "passive";
+ };
+ };
+
+ cooling-maps {
+ map0 {
+ trip = <&cpu_alert>;
+ cooling-device = <&cpu0 (-1) (-1)>;
+ };
+ map1 {
+ trip = <&cpu_alert>;
+ cooling-device = <&cpu2 (-1) (-1)>;
+ };
+ };
+ };
+ };