-rw-r--r--dts/src/arm/exynos5422-cpu-thermal.dtsi103
1 files changed, 0 insertions, 103 deletions
diff --git a/dts/src/arm/exynos5422-cpu-thermal.dtsi b/dts/src/arm/exynos5422-cpu-thermal.dtsi
deleted file mode 100644
index 3e4c4ad96d..0000000000
--- a/dts/src/arm/exynos5422-cpu-thermal.dtsi
+++ /dev/null
@@ -1,103 +0,0 @@
-/*
- * Device tree sources for Exynos5422 thermal zone
- *
- * Copyright (c) 2015 Lukasz Majewski <l.majewski@samsung.com>
- * Anand Moon <linux.amoon@gmail.com>
- *
- * This program is free software; you can redistribute it and/or modify
- * it under the terms of the GNU General Public License version 2 as
- * published by the Free Software Foundation.
- *
- */
-
-#include <dt-bindings/thermal/thermal.h>
-
-/ {
- thermal-zones {
- cpu0_thermal: cpu0-thermal {
- thermal-sensors = <&tmu_cpu0 0>;
- polling-delay-passive = <250>;
- polling-delay = <0>;
- trips {
- cpu_alert0: cpu-alert-0 {
- temperature = <50000>; /* millicelsius */
- hysteresis = <5000>; /* millicelsius */
- type = "active";
- };
- cpu_alert1: cpu-alert-1 {
- temperature = <60000>; /* millicelsius */
- hysteresis = <5000>; /* millicelsius */
- type = "active";
- };
- cpu_alert2: cpu-alert-2 {
- temperature = <70000>; /* millicelsius */
- hysteresis = <5000>; /* millicelsius */
- type = "active";
- };
- cpu_crit0: cpu-crit-0 {
- temperature = <120000>; /* millicelsius */
- hysteresis = <0>; /* millicelsius */
- type = "critical";
- };
- /*
- * Exyunos542x support only 4 trip-points
- * so for these polling mode is required.
- * Start polling at temperature level of last
- * interrupt-driven trip: cpu_alert2
- */
- cpu_alert3: cpu-alert-3 {
- temperature = <70000>; /* millicelsius */
- hysteresis = <10000>; /* millicelsius */
- type = "passive";
- };
- cpu_alert4: cpu-alert-4 {
- temperature = <85000>; /* millicelsius */
- hysteresis = <10000>; /* millicelsius */
- type = "passive";
- };
-
- };
- cooling-maps {
- map0 {
- trip = <&cpu_alert0>;
- cooling-device = <&fan0 0 1>;
- };
- map1 {
- trip = <&cpu_alert1>;
- cooling-device = <&fan0 1 2>;
- };
- map2 {
- trip = <&cpu_alert2>;
- cooling-device = <&fan0 2 3>;
- };
- /*
- * When reaching cpu_alert3, reduce CPU
- * by 2 steps. On Exynos5422/5800 that would
- * be: 1500 MHz and 1100 MHz.
- */
- map3 {
- trip = <&cpu_alert3>;
- cooling-device = <&cpu0 0 2>;
- };
- map4 {
- trip = <&cpu_alert3>;
- cooling-device = <&cpu4 0 2>;
- };
-
- /*
- * When reaching cpu_alert4, reduce CPU
- * further, down to 600 MHz (11 steps for big,
- * 7 steps for LITTLE).
- */
- map5 {
- trip = <&cpu_alert4>;
- cooling-device = <&cpu0 3 7>;
- };
- map6 {
- trip = <&cpu_alert4>;
- cooling-device = <&cpu4 3 11>;
- };
- };
- };
- };
-};