summaryrefslogtreecommitdiffstats
path: root/dts/src/arm64/marvell/armada-ap806.dtsi
diff options
context:
space:
mode:
Diffstat (limited to 'dts/src/arm64/marvell/armada-ap806.dtsi')
-rw-r--r--dts/src/arm64/marvell/armada-ap806.dtsi18
1 files changed, 15 insertions, 3 deletions
diff --git a/dts/src/arm64/marvell/armada-ap806.dtsi b/dts/src/arm64/marvell/armada-ap806.dtsi
index 7f799cb566..91dad7e4ee 100644
--- a/dts/src/arm64/marvell/armada-ap806.dtsi
+++ b/dts/src/arm64/marvell/armada-ap806.dtsi
@@ -283,6 +283,8 @@
ap_thermal: thermal-sensor@80 {
compatible = "marvell,armada-ap806-thermal";
reg = <0x80 0x10>;
+ interrupt-parent = <&sei>;
+ interrupts = <18>;
#thermal-sensor-cells = <1>;
};
};
@@ -293,16 +295,26 @@
* The thermal IP features one internal sensor plus, if applicable, one
* remote channel wired to one sensor per CPU.
*
+ * Only one thermal zone per AP/CP may trigger interrupts at a time, the
+ * first one that will have a critical trip point will be chosen.
+ *
* The cooling maps are always empty as there are no cooling devices.
*/
thermal-zones {
ap_thermal_ic: ap-thermal-ic {
- polling-delay-passive = <1000>;
- polling-delay = <1000>;
+ polling-delay-passive = <0>; /* Interrupt driven */
+ polling-delay = <0>; /* Interrupt driven */
thermal-sensors = <&ap_thermal 0>;
- trips { };
+ trips {
+ ap_crit: ap-crit {
+ temperature = <100000>; /* mC degrees */
+ hysteresis = <2000>; /* mC degrees */
+ type = "critical";
+ };
+ };
+
cooling-maps { };
};