From 35f607bc7da71b302fd6bf3d6d48d7ea66df1195 Mon Sep 17 00:00:00 2001 From: Sascha Hauer Date: Tue, 11 Sep 2018 08:26:30 +0200 Subject: dts: update to v4.19-rc1 Signed-off-by: Sascha Hauer --- dts/Bindings/thermal/thermal.txt | 11 +++-------- 1 file changed, 3 insertions(+), 8 deletions(-) (limited to 'dts/Bindings/thermal/thermal.txt') diff --git a/dts/Bindings/thermal/thermal.txt b/dts/Bindings/thermal/thermal.txt index cc553f0952..eb7ee91556 100644 --- a/dts/Bindings/thermal/thermal.txt +++ b/dts/Bindings/thermal/thermal.txt @@ -97,8 +97,8 @@ get assigned to trip points of the zone. The cooling devices are expected to be loaded in the target system. Required properties: -- cooling-device: A phandle of a cooling device with its specifier, - Type: phandle + referring to which cooling device is used in this +- cooling-device: A list of phandles of cooling devices with their specifiers, + Type: phandle + referring to which cooling devices are used in this cooling specifier binding. In the cooling specifier, the first cell is the minimum cooling state and the second cell is the maximum cooling state used in this map. @@ -276,12 +276,7 @@ thermal-zones { }; map1 { trip = <&cpu_alert1>; - cooling-device = <&fan0 5 THERMAL_NO_LIMIT>; - }; - map2 { - trip = <&cpu_alert1>; - cooling-device = - <&cpu0 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>; + cooling-device = <&fan0 5 THERMAL_NO_LIMIT>, <&cpu0 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>; }; }; }; -- cgit v1.2.3