* Actions S900 Clock Management Unit (CMU) The Actions S900 clock management unit generates and supplies clock to various controllers within the SoC. The clock binding described here is applicable to S900 SoC. Required Properties: - compatible: should be "actions,s900-cmu" - reg: physical base address of the controller and length of memory mapped region. - clocks: Reference to the parent clocks ("hosc", "losc") - #clock-cells: should be 1. Each clock is assigned an identifier, and client nodes can use this identifier to specify the clock which they consume. All available clocks are defined as preprocessor macros in dt-bindings/clock/actions,s900-cmu.h header and can be used in device tree sources. External clocks: The hosc clock used as input for the plls is generated outside the SoC. It is expected that it is defined using standard clock bindings as "hosc". Actions S900 CMU also requires one more clock: - "losc" - internal low frequency oscillator Example: Clock Management Unit node: cmu: clock-controller@e0160000 { compatible = "actions,s900-cmu"; reg = <0x0 0xe0160000 0x0 0x1000>; clocks = <&hosc>, <&losc>; #clock-cells = <1>; }; Example: UART controller node that consumes clock generated by the clock management unit: uart: serial@e012a000 { compatible = "actions,s900-uart", "actions,owl-uart"; reg = <0x0 0xe012a000 0x0 0x2000>; interrupts = ; clocks = <&cmu CLK_UART5>; };