* Rockchip RV1108 Clock and Reset Unit The RV1108 clock controller generates and supplies clock to various controllers within the SoC and also implements a reset controller for SoC peripherals. Required Properties: - compatible: should be "rockchip,rv1108-cru" - reg: physical base address of the controller and length of memory mapped region. - #clock-cells: should be 1. - #reset-cells: should be 1. Optional Properties: - rockchip,grf: phandle to the syscon managing the "general register files" If missing pll rates are not changeable, due to the missing pll lock status. Each clock is assigned an identifier and client nodes can use this identifier to specify the clock which they consume. All available clocks are defined as preprocessor macros in the dt-bindings/clock/rv1108-cru.h headers and can be used in device tree sources. Similar macros exist for the reset sources in these files. External clocks: There are several clocks that are generated outside the SoC. It is expected that they are defined using standard clock bindings with following clock-output-names: - "xin24m" - crystal input - required, - "ext_vip" - external VIP clock - optional - "ext_i2s" - external I2S clock - optional - "ext_gmac" - external GMAC clock - optional - "hdmiphy" - external clock input derived from HDMI PHY - optional - "usbphy" - external clock input derived from USB PHY - optional Example: Clock controller node: cru: cru@20200000 { compatible = "rockchip,rv1108-cru"; reg = <0x20200000 0x1000>; rockchip,grf = <&grf>; #clock-cells = <1>; #reset-cells = <1>; }; Example: UART controller node that consumes the clock generated by the clock controller: uart0: serial@10230000 { compatible = "rockchip,rv1108-uart", "snps,dw-apb-uart"; reg = <0x10230000 0x100>; interrupts = ; reg-shift = <2>; reg-io-width = <4>; clocks = <&cru SCLK_UART0>; };