* Bosch BMA180 / BMA250 triaxial acceleration sensor http://omapworld.com/BMA180_111_1002839.pdf http://ae-bst.resource.bosch.com/media/products/dokumente/bma250/bst-bma250-ds002-05.pdf Required properties: - compatible : should be "bosch,bma180" or "bosch,bma250" - reg : the I2C address of the sensor Optional properties: - interrupt-parent : should be the phandle for the interrupt controller - interrupts : interrupt mapping for GPIO IRQ, it should by configured with flags IRQ_TYPE_LEVEL_HIGH | IRQ_TYPE_EDGE_RISING For the bma250 the first interrupt listed must be the one connected to the INT1 pin, the second (optional) interrupt listed must be the one connected to the INT2 pin. Example: bma180@40 { compatible = "bosch,bma180"; reg = <0x40>; interrupt-parent = <&gpio6>; interrupts = <18 (IRQ_TYPE_LEVEL_HIGH | IRQ_TYPE_EDGE_RISING)>; };