=========================================== C-SKY Multi-processors Interrupt Controller =========================================== C-SKY Multi-processors Interrupt Controller is designed for ck807/ck810/ck860 SMP soc, and it also could be used in non-SMP system. Interrupt number definition: 0-15 : software irq, and we use 15 as our IPI_IRQ. 16-31 : private irq, and we use 16 as the co-processor timer. 31-1024: common irq for soc ip. ============================= intc node bindings definition ============================= Description: Describes SMP interrupt controller PROPERTIES - compatible Usage: required Value type: Definition: must be "csky,mpintc" - #interrupt-cells Usage: required Value type: Definition: must be <1> - interrupt-controller: Usage: required Examples: --------- intc: interrupt-controller { compatible = "csky,mpintc"; #interrupt-cells = <1>; interrupt-controller; };