Device-Tree bindings for charger of Active-semi ACT8945A Multi-Function Device Required properties: - compatible: "active-semi,act8945a-charger". - active-semi,chglev-gpios: charge current level phandle with args as described in ../gpio/gpio.txt. - active-semi,lbo-gpios: specify the low battery voltage detect phandle with args as as described in ../gpio/gpio.txt. - interrupts: where a is the interrupt number and b is a field that represents an encoding of the sense and level information for the interrupt. - interrupt-parent: the phandle for the interrupt controller that services interrupts for this device. Optional properties: - active-semi,input-voltage-threshold-microvolt: unit: mV; Specifies the charger's input over-voltage threshold value; The value can be: 6600, 7000, 7500, 8000; default: 6600 - active-semi,precondition-timeout: unit: minutes; Specifies the charger's PRECONDITION safety timer setting value; The value can be: 40, 60, 80, 0; If 0, it means to disable this timer; default: 40. - active-semi,total-timeout: unit: hours; Specifies the charger's total safety timer setting value; The value can be: 3, 4, 5, 0; If 0, it means to disable this timer; default: 3. Example: pmic@5b { compatible = "active-semi,act8945a"; reg = <0x5b>; charger { compatible = "active-semi,act8945a-charger"; pinctrl-names = "default"; pinctrl-0 = <&pinctrl_charger_chglev &pinctrl_charger_lbo &pinctrl_charger_irq>; interrupt-parent = <&pioA>; interrupts = <45 GPIO_ACTIVE_LOW>; active-semi,chglev-gpios = <&pioA 12 GPIO_ACTIVE_HIGH>; active-semi,lbo-gpios = <&pioA 72 GPIO_ACTIVE_LOW>; active-semi,input-voltage-threshold-microvolt = <6600>; active-semi,precondition-timeout = <40>; active-semi,total-timeout = <3>; }; };