Lantiq Synchronous Serial Controller (SSC) SPI master driver Required properties: - compatible: "lantiq,ase-spi", "lantiq,falcon-spi", "lantiq,xrx100-spi" - #address-cells: see spi-bus.txt - #size-cells: see spi-bus.txt - reg: address and length of the spi master registers - interrupts: should contain the "spi_rx", "spi_tx" and "spi_err" interrupt. Optional properties: - clocks: spi clock phandle - num-cs: see spi-bus.txt, set to 8 if unset - base-cs: the number of the first chip select, set to 1 if unset. Example: spi: spi@e100800 { compatible = "lantiq,xrx200-spi", "lantiq,xrx100-spi"; reg = <0xE100800 0x100>; interrupt-parent = <&icu0>; interrupts = <22 23 24>; interrupt-names = "spi_rx", "spi_tx", "spi_err"; #address-cells = <1>; #size-cells = <1>; num-cs = <6>; base-cs = <1>; };