From 9d99842f99d847191ebd0c28469d2c70fcc5bf9e Mon Sep 17 00:00:00 2001 From: Zhang Rui Date: Tue, 26 Jun 2012 16:35:57 +0800 Subject: Thermal: set upper and lower limits set upper and lower limits when binding a thermal cooling device to a thermal zone device. Signed-off-by: Zhang Rui Reviewed-by: Rafael J. Wysocki Reviewed-by: Eduardo Valentin --- Documentation/thermal/sysfs-api.txt | 9 ++++++++- 1 file changed, 8 insertions(+), 1 deletion(-) (limited to 'Documentation') diff --git a/Documentation/thermal/sysfs-api.txt b/Documentation/thermal/sysfs-api.txt index c087dbcf3535..ca1a1a34970e 100644 --- a/Documentation/thermal/sysfs-api.txt +++ b/Documentation/thermal/sysfs-api.txt @@ -84,7 +84,8 @@ temperature) and throttle appropriate devices. 1.3 interface for binding a thermal zone device with a thermal cooling device 1.3.1 int thermal_zone_bind_cooling_device(struct thermal_zone_device *tz, - int trip, struct thermal_cooling_device *cdev); + int trip, struct thermal_cooling_device *cdev, + unsigned long upper, unsigned long lower); This interface function bind a thermal cooling device to the certain trip point of a thermal zone device. @@ -93,6 +94,12 @@ temperature) and throttle appropriate devices. cdev: thermal cooling device trip: indicates which trip point the cooling devices is associated with in this thermal zone. + upper:the Maximum cooling state for this trip point. + THERMAL_NO_LIMIT means no upper limit, + and the cooling device can be in max_state. + lower:the Minimum cooling state can be used for this trip point. + THERMAL_NO_LIMIT means no lower limit, + and the cooling device can be in cooling state 0. 1.3.2 int thermal_zone_unbind_cooling_device(struct thermal_zone_device *tz, int trip, struct thermal_cooling_device *cdev); -- cgit v1.2.3